 Energy Management Modular Power Analyzers Type WM2-96
* Class 1 (current/voltage) * Modular power analyzer * Front size: 96x96 mm * 3-dgt/6-dgt P-based indicator * Manual or automatic scrolling of system and single phase: kW, kVAr, PF, kWh, kVArh, A, VL-L avg, VL1-N, VL2-N, VL3-N. * TRMS measurement of distorted waves (voltage/current) * All configuration functions selectable by built-in key-pad * Password protection of programming parameters * Degree of protection (front): IP 65 * Optional pulse output (according to DIN43864) * Optional serial RS 422 /485 port * MODBUS, JBUS protocol.
Product Description
P-based modular power analyzer with a built-in configuration key-pad. The power, power factor, current and voltage are system and single phase measurements and indications. The housing is easy to mount on a panel and ensures a degree of protection (front) of IP 65.
Ordering Key WM2-96 AV53D XXX
Model Range code System Power supply 1st output 2nd output
Type Selection
Range code AV5: AV7: 250/433 VAC - 5 AAC (max. 300 V (L-N)/ 520 V (L-L) - 6 A) 400/690 VAC - 5 AAC (max. 480 V (L-N)/ 830 V (L-L) - 6 A) 1) System 3: One phase, three-phase system, 3 or 4 wires, balanced load; three phase system, 3 or 4 wires, unbalanced load Power supply A: B: C: D: L: H: 24 VAC, -15% +10%, 50/60 Hz 1) 2) 48 VAC, -15%+10%, 50/60 Hz 1) 2) 115 VAC, -15% +10%, 50/60 Hz 1) 2) 230 VAC, -15% +10%, 50/60 Hz (standard) 2) 18 to 60 VDC/AC 3) 90 to 260 VDC/AC 3) 1st output (pulse) XX: O1: No output (standard) Single open collector output (30V/100mADC) 1) O2: Dual open collector output, the second one is the copy of the first one, like "O1" 1) R1: Single relay output, (AC1-8AAC, 250VAC) 1) R2: Dual relay output, the second one is the copy of the first one, like "R1" 1) 2nd output X: S: No output (standard) Serial port, RS 485 multidrop bidirectional 1)
1) 2)
3)
On request Warning: this power supply cannot be used if the RS485 module is needed Compatible with any kind of output
Input Specifications
Accuracy (48 to 62 Hz) Voltage/current (@ 25C 5C, R.H. 60%) Active power (@ 25C 5C, R.H. 60%) Reactive power (@ 25C 5C, R.H. 60%) Power factor (PF) (@ 25C 5C, R.H. 60%) Energy (@ 25C 5C, R.H. 60%) Additional errors Humidity Power supply Magnetic field Un: 250V (AV5), 400V (AV7) In: 5A 0.5% f.s. (0 to 1.2 In, 0.5 to 1.2 Un) 1% f.s. (PF 0.7 L/C, 0 to 1.2 In, 0.5 to 1.2 Un) 1% f.s. (PF 0.7 L/C, 0 to 1 In, 0 to 1 Un) 1% f.s., PF 0.7 L/C, (0.6 to 1.2 In, 1 to 1.2 Un) 1% RDG (kWh), 2% RDG (kvarh), (PF 0.7L/C, 0 to 1.2 In, 0.5 to 1.2 Un) < 0.3% f.s., 60% to 90% R.H. 0.5% rdg, -15 +10% p.s. < 0.1% f.s. @ 400 A/m
WM2-96DS0303
Rated input Current
Voltage
Insulation
Temperature drift Display
2 inputs (one/three-phase balanced load) 6 inputs (one/three-phase unbalanced load) 2 inputs (one/three-phase balanced load) 4 inputs (one/three-phase unbalanced load) among the voltage and the current inputs: 2000Vrms; among the current inputs: 2000 Vrms 250 ppm/C Backlighted LCD, h 13mm, 3-dgt (instantaneous meas.) 6-dgt (energies)
Specifications are subject to change without notice
1
WM2-96
Input Specifications (cont.)
Decimal point position Instantaneous measurements: Automatic selection according to the current transformer ratio of the CT being connected (max. indication single phase): CT ratio 5 : 11.11 (25.00A) CT ratio 50.0: 111.1 (250.0A) CT ratio 500.0 : 1111 (2500A) CT ratio 999.9 : 11110 (6000A) Energy measurements: max. resolution:1 Wh/1 VArh min. resolution: 1 kWh/1 kVArh Max. 600 min. 0 Max. 6.00 min. 0.00 Max. 1.00 min. 0.00 Max. 5.40 min. 0.00 Max. 999999 min. -199999 Max. 999999 min. 0 3 times / second kW, kVAr, PF, VL-L, A, kWh, kvarh kWh, kvarh (the meters are reset automatically when the values reach 14999*CT ratio) kW, kVAr, PF, VL-N, A TRMS measurement of a distorted voltage/current wave Coupling type: Direct Crest factor: 3 Ranges (impedances) 250 V/433 V (400k) 5 AAC ( 0.3 VA / 0.1) 400V/690V (650k) 48 to 62 Hz Un: 250V (AV5), 400V (AV7) In: 5A 1.2 Un /In 2 Un 20 In 4 keys: "": - to enter programming phase and password confirmation; - for value programming and basic measurement scrolling. "L": - for confirmation of new programmed values and going ahead to the next programming step, - single phase measurement scrolling. "R": - for the reset of the partial counted active and/or reactive energy.
Frequency range Over-load protection Continuous: voltage/current For 1 s Voltage: Current: Keyboard
Max. and min. indication Voltage Current (CT ratio = 1) PF Power (CT ratio = 1) Active energy Reactive energy Sampling rate Measurements System variables Total energies Partial energies
Single phase variables Measurement method
Output Specifications
Pulse output (on request) Number of outputs Static type (according to DIN 43864) Protocol 1, independent From 0.1 to 999.9 programmable pulses for kWh, KVArh, open collector (NPN transistor) VON 1.2 VDC/ max. 100 mA VOFF 30 VDC max. 1 x SPDT AC 1 - 8A, 250VAC DC 12 - 5A,24VDC AC 15 - 2.5A, 250VAC DC 13 - 2.5A, 24VDC 200 ms (ON), 200 ms (OFF) By means of optocouplers, 4000 Vrms output to measuring input, 4000 Vrms output to supply input. RS422/RS485; Multidrop bidirectional (static and dynamic variables) 4 wires, max. distance 1200m, termination directly on the module 1 to 255, selectable by key-pad Data (bidirectional) Dynamic (reading only) MODBUS/JBUS System variables: P, Q, PF, VL-L, energies, Single phase variables: PL1, QL1, PFL1, VL1-N, AL1, PL2, QL2, PFL2, VL2-N, AL2, PL3, QL3, PFL3, VL3-N, AL3 All programming data, reset of energy: - partial kWh - partial kVArh - total kWh - total kVArh Stored energy (EEPROM) 999999 kWh 999999 kVArh 1-start bit, 8-data bit, no parity/even parity, 1 stop bit 1200, 2400, 4800 and 9600 selectable bauds By means of optocouplers, 4000 Vrms output to measuring inputs 4000 Vrms output to supply input
WM2-96DS0303
Relay type
Static (writing only)
Pulse duration Insulation
Serial port (on request) Type Connections Addresses
Data format Baud-rate Insulation
2
Specifications are subject to change without notice
WM2-96
Software Functions
Password 1st level 2nd level Measurement scrolling System: Numeric code of max. 3 digits; 2 protection levels of the programming data Password "0", no protection Password from 1 to 255, all data are protected Active power (kW), reactive power (kVAr), power factor (cos ), current (A), average phase-phase voltage (V) total and partial active energy (kWh), total and partial reactive energy (kVArh) Partial energy meters: the counters of kWh and kVArh are automatically reset when the energy reaches the value (14999*CT). Example: the CT is a 100A/5A so the ratio is 20, consequently the maximum counted energy is 299980 kWh or kVArh. Active power (kW), reactive power (kVAr), power factor (cos ), current (A), phase-neutral voltage (V) For CT up to 5000 A 0.1 to 999.9 0 to 100% of the input electrical scale 1 to 64 On the display and on the variable being transmitted by the serial communication port.
Single phase:
Transformer ratio Programmable ratio Digital Filter Filter operating range Filtering coefficient Filter action
Supply Specifications
AC voltage 230 VAC (standard), -15%+10% 50/60 Hz 24 VAC, 48 VAC, 115 VAC (on request), -15%+10% 50/60 Hz 18 to 60VDC/AC Power consumption 90 to 260VDC/AC 30VA / 12W (90 to 260V) 20VA / 12W (18 to 60V)
General Specifications
Operating temperature Storage temperature Insulation reference voltage Insulation Dielectric strength Noise rejection CMRR EMC 0 to +50C (32 to 122F) (R.H. < 90% non-condensing) -10 to +60C (14 to 140F) (R.H. < 90% non-condensing) 300 Vrms to ground 4000 Vrms between all inputs/ outputs to ground 4000 Vrms for 1 minute 100 dB, 48 to 62 Hz EN 50081-2, EN 50082-2 Safety standards Other standards Approvals Connector Housing Dimensions Material Degree of protection Weight IEC 61010-1, EN 61010-1 Pulse output: DIN43864 CE UL, CSA Screw-type, max. 2.5 mm2 wires x 2 96 x 96 x 140 mm ABS, self-extinguishing: UL 94 V-0 Front: IP65 Approx. 500 g (packing included)
Specifications are subject to change without notice
WM2-96DS0303
3
WM2-96
Mode of Operation
Accuracy class of the instrument as a relation of PI/Pn and cos (power factor) PI / Pn Active Power QI / Qn Reactive Power
2%
2%
1% 1% 5%
Test conditions: V = 0.8 to 1.2 Un, I = 0.1 to 1.2 In, f = 48 to 62 Hz
Test conditions: V = 0.8 to 1.2 Un, I = 0.1 to 1.2 In, f = 48 to 62 Hz
Input AV5
Star voltage Un: 250 V
Delta voltage Un: 430 V
Current In: 5 A
Example 1: Model AV5.3 (3-wire system).
UI = 400 V (delta voltage) II = 265 A (single phase cur-
Example 2: Model AV5.3 (4-wire system).
UI = 230 V II = 110 A (CT=300A) Cos = 0.85 (sin = 0.52) Un = 250 V In = 5 A CT (ratio) = 300 A = 60 5A Qn = 3 * UI * II * sin = 3 * 230 * 110 * 0.52 = 39.46 kvar Qn = 3 * Un * In * CT (ratio) = 3 * 250 * 5 * 60 = 225 kvar 39.46 PI = = 0.175 Pn 225
rent)
Cos = 0.85 (system power factor) (CT=300A) Un = 430 V In = 5 A CT (ratio) = 300 = 60 5 PI = 3 * UI * II * cos = 3 * 400 * 265 * 0.85 = 155.87 kW Pn = 3 * Un * In * CT (ratio) = 3 * 430 * 5 * 60 = 233.17 kW PI 155.87 = = 0.698 Pn 223.17
PI/QI (installation power) One phase system:
PI = UI * II * cos QI = UI * II * sin
Pn /Qn (rated power of the instrument): One phase system:
Pn = Qn = Un * In * CT(ratio)
Three phase, 3-wire system:
PI = 3 * UI * II * cos QI = 3 * UI * II * sin
Three phase, 3-wire system:
Pn = Qn = 3 * Un * In * CT(ratio)
Three phase, 4-wire system:
PI = 3 * UI * II * cos QI = 3 * UI * II * sin
Three phase, 4-wire system:
Pn = Qn = 3 * Un * In * CT(ratio)
where: UI = the real star voltage of the electrical system being measured. I = the maximum phase current of the electrical system being measured. Cos = the average cos of the electrical system being measured.
where: Un = the rated input voltage of WM2-96. In = the rated input current of WM2-96. CT (ratio) = the value of the current transformer ratio.
In both examples the accuracy of the measurement is 1% f.s. when considering the changing of the measured voltage from 0.9 Un to 1 Un and the measured current from 0.1 In to 0.9 In with a cos of 0.85 (sin 0.52).
4
Specifications are subject to change without notice
WM2-96DS0303
WM2-96
Mode of Operation (cont.)
Waveform of the signals that can be measured
Figure G Sine wave, undistorted Fundamental content 100% Harmonic content 0% 1.1107 | A | Arms =
Figure H Sine wave, indented Fundamental content 10...100% Harmonic content 0...90% Frequency spectrum 3rd to 16th harmonic Required result: additional error < 1%
Figure I Sine wave, distorted Fundamental content 70...90% Harmonic content 10...30% Frequency spectrum 3rd to 15th harmonic Required result: additional error < 0.5%
Wiring Diagrams
Single phase input connections Fig. 1
1 3
L2
Fig. 2
1 3
L2
5
L3
I
L1
8 L1
7 N L2 9
10 L3
5
L3
2
4
6
U
I
L1
8 L1
7 N L2 9
10 L3
2
4
6
U
L1 N
L1 N
Direct connection
CT connection
Three phase 3-wire input connections - Balanced loads Fig. 3 Fig. 4
Direct connection (3-wire system)
CT connection (3-wire system)
Specifications are subject to change without notice
WM2-96DS0303
5
WM2-96
Wiring Diagrams (cont.)
Three phase, 4-wire input connections - Balanced loads Fig. 5 Fig. 6
Direct connection (4-wire system)
CT connection (4-wire system)
Three-phase, 3-wire input ARON connections Unbalanced load Fig. 7
Three-phase, 3-wire input connections Unbalanced load Fig. 8
CT connection (3-wire system)
CT connection (3-wire system)
Three phase, 4-wire input connections - Unbalanced load Fig. 9 Fig. 10
Direct connection (4-wire system)
CT connection (4-wire system)
6
Specifications are subject to change without notice
WM2-96DS0303
WM2-96
Front Panel Description
- To enter into the programming procedure and select programming functions together with the "L" key. "L": To scroll all the single phase variable of each basic measurement "R": To reset the partial counted energies (kWh, kVArh). 2. Display Instantaneous measurements: - 3-digit (maximum read-out 999) Energies: - 6-digit (maximum read-out 999999). Alphanumeric indication by means of LCD display for: - Displaying the configuration parameters - All the measured variables.
2
1
1. Key-pad Set-up and programming procedures are easily controlled by the 4 pushbuttons.
L and M - To scroll all the basic measurements (system variables) - To increase or decrease programming values
Sequence of the variables on the display
SYSTEM VARIABLE
V
L1 - L2 - L3 (average)
PHASE 1
V L1 (V L1-N )
SINGLE PHASE VARIABLES PHASE 3 PHASE 2 L L
V L2 (V L2-N )
L
L
V L3 (V L3-N )
I L1 L2 L3
L
I
L1
L L
I
L2
L
I
L3
cos
L1 L2 L3
L
cos
L1
L L
cos
L2
L
cos
L3
kW
L1 L2 L3
L
kW
L1
L L
kW L2
L
kW L3
kVAr
L1 L2 L3
L
kVAr
L1
L L
kVAr
L2
L
kVAr
L3
kWh
total
L L
kWh
partial
kVARh
total
L L
kVARh
partial
Specifications are subject to change without notice
WM2-96DS0303
7
WM2-96
The available modules
Type WM2-96 base + AV5.3 input WM2-96 base + AV7.3 input 24VAC power supply 48VAC power supply 115VAC power supply 230VAC power supply 18-60VAC/DC power supply 90-260VAC/DC power supply RS485 port Relay output Relay output Open collector output Open collector output N. of channels Ordering code AB1012 AB1013 AP1025 AP1024 AP1023 AP1022 AP1021 AP1020 AR1034 AO1058 AO1035 AO1059 AO1036 Note
Neither UL nor CSA approved Neither UL nor CSA approved Neither UL nor CSA approved Neither UL nor CSA approved
1 1 2 1 2
The second output can be used as redoundant output The second output can be used as redoundant output
The possible module combinations
Slot Basic unit RS485 port Single relay output (pulse) Single open collector output (pulse) B Out 1 D Out 2 Slot Basic unit RS485 port Dual relay output (pulse) Dual open collector output (pulse) B Out 1 D Out 2
Dimensions
8
Specifications are subject to change without notice
WM2-96DS0303
WM2-96
Terminal boards
Digital output modules
AO1058 Single relay output Other input/output modules
AO1035 Dual relay output
AO1059 Single open collector output
AO1036 Dual open collector output
AR1034 RS485 port
Power supply modules
AP1025 24VAC power supply
AP1024 48VAC power supply
AP1023 115VAC power supply
AP1022 230VAC power supply
AP1021 18-60VAC/DC power supply
AP1020 90-260 VAC/DC power supply
Specifications are subject to change without notice
WM2-96DS0303
9


▲Up To Search▲   

 
Price & Availability of WM2-96AV53D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X